Recently, the Department of Ecology and Environment of Guangdong Province issued the "Approval and Announcement of the Department of Ecology and Environment of Guangdong Province on the Eco-environmental Impact Report of the Energy-saving and Environmental Protection Technical Reform Project of Huizhou Tapai Cement Co., Ltd." Improve cement I. Your company is located in Huizhou Longmen Industrial Park, Pingling Street, Longmen County, Huizhou City. The original environmental impact assessment approved the construction of two 4500 tons/day new dry process clinker lines, with an annual production of 310 days and an annual output of 2.79 million tons of cement clinker. This project does not change the main equipment of cement kiln, but improves the production capacity of cement clinker through partial transformation, auxiliary equipment replacement and energy-saving and environmental protection transformation. After the implementation of the project, the production capacity of the two cement clinker production lines will be 2 × 5333 tons/day, with an annual output of 300 days and an annual output of 2 × 159 cement clinker. On the premise of fully implementing the pollution prevention and control and environmental risk prevention measures proposed in the report and ensuring the stable discharge of various pollutants up to the standard, the project is constructed in accordance with the nature, scale, location, production process and measures to prevent pollution and ecological damage listed in the report, which is feasible from the perspective of ecological environment protection. In the construction and operation of the project, we should also focus on the following tasks: (1) Strictly implement air pollution prevention and control measures. Hydrogen chloride, hydrogen fluoride, mercury and its compounds, thallium, cadmium, lead, arsenic and their compounds, beryllium, chromium, tin, antimony, copper, cobalt, manganese, nickel, vanadium and their compounds in the waste gas of the waste heat utilization system of the cement kiln and the kiln tail, Dioxins and other pollutants are discharged in accordance with "Table 1 Maximum Allowable Emission Concentration of Air Pollutants in Cement Kiln for Co-disposal of Solid Wastes" in Pollution Control Standard for Co-disposal of Solid Wastes in Cement Kiln (GB 30485 — 2013). Emission of pollutants such as nitrogen oxides, particulate matter, sulfur dioxide, ammonia and fluoride in waste gas from cooler and material handling, storage, pretreatment and transportation, as well as waste gas from cement kiln and waste heat utilization system at kiln tail shall be in accordance with the Emission Standard of Air Pollutants for Cement Industry (GB 4915-2013). Including the amendment list), and shall comply with the relevant provisions of the state and our province on ultra-low emission of cement industry. The height of each exhaust funnel shall not be lower than recommended value in the report. Take measures such as workshop closure to reduce the unorganized emission of waste gas. The emission of particulate matter, ammonia and other pollutants at the factory boundary of the enterprise shall be in accordance with "Table 3 Unorganized Emission Limits of Air Pollutants" in (GB 4915 — 2013, including amendments); the concentration of hydrogen sulfide and odor shall be in accordance with the standard values for new expansion and reconstruction of Class II in "Table 1 Standard Values for Odor Pollutants at the Factory Boundary" in the Emission Standard for Odor Pollutants (GB 14554 — 93). The project shall set a certain environmental protection distance according to the demonstration results of the report, and cooperate with the local government and relevant departments to do a good job in the planning of land use within the environmental protection distance. It is strictly forbidden to build schools, residential buildings and other environmentally sensitive objects. (Two) strictly implement water pollution prevention and control measures. Production wastewater, domestic sewage and initial rainwater shall be reused for production after treatment and shall not be discharged. Reasonable division of anti-seepage areas, and strict implementation of anti-seepage and other control measures and tracking monitoring, hidden danger investigation and other requirements to prevent pollution of soil and groundwater environment. (Three) strictly implement noise pollution prevention and control measures. Low-noise equipment is selected, and effective measures such as sound insulation and noise reduction are taken to ensure that the noise at the factory boundary meets the emission limits of three types of acoustic environmental function zones in the Emission Standard for Environmental Noise at the Factory Boundary of Industrial Enterprises (GB 12348 — 2008). (4) Strictly implement the requirements for classified treatment and disposal of solid waste. Pollution prevention and control of hazardous wastes such as waste denitration catalysts and waste dust removal bags generated in the storage, treatment and disposal of hazardous wastes shall strictly comply with the relevant provisions of hazardous waste management, and shall be sent to qualified units for treatment and disposal or relying on existing cement production facilities for treatment and disposal. General industrial solid wastes such as wastewater treatment sludge and scrap iron are treated and disposed of by existing cement production facilities or sent to units with utilization capacity for comprehensive utilization. When entrusting others to transport, utilize and dispose of industrial solid waste, the principal qualification and technical ability of the entrusted party shall be verified, a written contract shall be signed according to law, and the requirements for pollution prevention and control shall be stipulated in the contract. (5) Establish and improve the emergency response system for environmental risk accidents, and improve and strictly implement environmental risk prevention measures and contingency plan. Emergency pools for wastewater accidents with sufficient volume should be set up to strengthen the management and maintenance of pollution prevention and environmental risk provention and control facilities, so as to effectively prevent environmental pollution accidents. (Six) strengthen environmental management during the construction period to prevent environmental pollution or ecological damage caused by engineering construction. The construction time shall be reasonably arranged, and the construction noise shall comply with the Emission Standard for Construction Noise (GB 12523 — 2025). (7) Setting up sewage outlets in accordance with the relevant provisions of the state and provinces, installing on-line monitoring systems for major pollutants, and implementing networked monitoring in accordance with the requirements of local ecological environment departments. Carry out pollutant discharge monitoring and environmental quality monitoring according to regulations. (Eight) improve the management system and strengthen the ecological environment management of enterprises. Establish smooth channels for public participation, actively release environmental information of enterprises, consciously accept social supervision, and timely solve the reasonable ecological environment demands of the public. (9) In accordance with the concepts of green development, circular economy and clean production, we should strengthen energy-saving and consumption-reducing measures and coordinate the control of pollutants and carbon emissions. (10) At the same time, the implementation of the project should speed up the transformation of ultra-low emissions in the whole process. Plant pollution control technology, pollutant discharge, monitoring and control, environmental management, The transportation mode shall comply with the requirements of the Opinions on Promoting the Implementation of Ultra-low Emission in Cement Industry (Huan Atmosphere [2024] No.5) and the Work Plan for the Ultra-low Emission Transformation of Cement Industry in Guangdong Province (Yue Huan [2024] No.7), as well as the requirements of the national and provincial A-level enterprises for environmental protection performance in cement industry. According to the relevant national and provincial regulations, before your company completes the ultra-low emission transformation of the whole process and the environmental protection performance reaches the A-level enterprise, the supplementary production capacity of this project shall not be put into operation, and the nitrogen oxide emission of the whole plant shall be controlled within 371.26 tons/year; After the completion of the whole process of ultra-low emission transformation and the environmental performance of A-level enterprises, the nitrogen oxide emissions of the whole plant should be controlled at 383. Your company should timely complete the evaluation of the whole process of ultra-low emission transformation and environmental performance level in accordance with the relevant requirements of the state and the province. 3. The environmental protection investment of the project shall be included in the project investment budget estimate and implemented. 4. After the approval of the report, if the nature, scale, location, production process or measures to prevent pollution and ecological damage of the project are to be significantly changed, your company shall re-submit the ecological environmental impact assessment documents of the construction project for approval according to law. 5. Your company should implement the main responsibility of ecological environment protection, strengthen the management of ecological environment, and promote the implementation of various ecological environment protection measures. The project construction must strictly implement the "three simultaneous" system of environmental protection in which the environmental protection facilities and the main works are designed, constructed and put into operation at the same time, and incorporate the optimized and refined ecological environmental protection measures and budget estimates into the design, construction, supervision and other bidding documents and contracts to clarify the responsibilities. Your company shall, in accordance with the Regulations on the Administration of Pollutant Discharge Permits and other relevant provisions, go through the formalities for pollutant discharge permits in a timely manner according to law. After the project is completed and put into operation, the completion environmental protection acceptance shall be carried out in accordance with the prescribed procedures. 6. The Department of Ecological Environment of Huizhou City shall strictly implement the responsibility of territorial supervision after the event, and shall implement the "Three Simultaneous" of Environmental Protection of Construction Projects and the Independent Acceptance and Supervision Mechanism of Environmental Protection of Completed Projects "in accordance with the requirements of the Ministry of Ecological Environment (No.70 of Environmental Law Enforcement 2021). Strengthen the supervision of "three simultaneous" and independent acceptance of the ecological environment protection of the project. Your company should accept the daily supervision and inspection of the ecological environment department according to the regulations. Announcement period of Department of Ecology and Environment of Guangdong Province on October 19 , 2026:30 days from the date of publication of this announcement. Notification of administrative reconsideration and administrative litigation rights: Citizens, legal persons or other organizations (except construction units) who believe that specific administrative acts infringe upon their legitimate rights and interests may apply to the Guangdong Provincial People's Government for reconsideration within 60 days from the expiration of the announcement period. It may also directly bring a suit in a people's court with jurisdiction within six months from the date of expiration of the time limit for the announcement.
浙公网安备33010802003254号