Recently, the Emergency Management Bureau of Hailar District, Hulunbuir, Inner Mongolia, issued a document saying that there are seven potential safety hazards in Hailar Mengxi Cement . It involves many workshops and related equipment, and the enterprise has serious omissions in safety management. The potential
safety hazards include: no emergency stop rope is set on one side of the 127m belt in the raw material workshop; no safety warning sign is set on the manhole of the high-temperature fan at the kiln tail in the clinker workshop; the maintenance springboard in the waste heat power generation workshop is not fully paved and bound; The cable bridge of the raw material low-voltage distribution room is not blocked at the wall; the valve port of a pipeline in the ammonia water room is not blocked; the pressure relief port of the dry bag-type dust remover in the pulverized coal preparation workshop and the dust remover on the top of the pulverized coal bunker is not set in the dust chamber; the cooling water pipe network is laid above the distribution cabinet in the distribution room at the kiln tail of the rotary kiln.